فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها



گروه تخصصی







متن کامل


نویسندگان: 

Farrokh Ebrahim

اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    53
  • شماره: 

    8
  • صفحات: 

    3577-3592
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    63
  • دانلود: 

    0
چکیده: 

In urban areas, tunneling is accompanied by ground surface settlement. To reduce the risks of the operation, it is always required to have an assessment of ground surface settlement and face pressure. In the evaluation of the face pressure, there are two major sets of methods based on the ultimate limit state (ULS) (e. g. tunnel face failure), and SERVICEABILITY limit state (SLS) (e. g. unacceptable settlement or heave). In a SERVICEABILITY limit state, volume loss and surface settlement are used for the analysis of the face pressure. The methods developed for the analysis of SLS face pressure are based on the results of small-scale centrifuge tests or case studies with the unpressurized face. Hence, realistic face pressure cannot be evaluated with these methods. This paper summarizes the major strategies for the evaluation of face pressure in an undrained condition. The outlined methods are utilized to evaluate tunnel face pressure in the Tehran metro line 6, south extension (ML6-SE) project. Results of the analyses showed that predicted face pressures with the SLS methods are far above the required face pressure. To make realistic SLS face pressure evaluations in this project (considering a maximum allowable surface settlement of 10 mm), using ground characteristics and TBM operational parameters, a new formula was introduced with a coefficient of determination of 84%. The results of this paper can be very helpful for both the design phase of a tunneling project and the construction period to adjust the face pressure based on the requirement of the allowable surface settlement.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 63

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1384
  • دوره: 

    1
  • شماره: 

    1
  • صفحات: 

    1-9
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    877
  • دانلود: 

    151
چکیده: 

برنامه ریزی حرکت قطارها به صورت دوره ای و تناوبی انجام می شود و از مهم ترین مسایل مربوط به بهره برداری بهینه از راه آهن است. در این نوع برنامه ریزی معمولا به یکی از پارامترهای مربوط از قبیل، زمان، فاصله، هزینه، ظرفیت و ... پرداخته می شود، اما این مساله تابع پارامترهای متعددی است و باید با توجه به روابط بین آنها بررسی شود. لذا در این مقاله ارایه یک مدل چند منظوره به عنوان راه حل اصلی برای این نوع برنامه ریزی انتخاب شده است. در این مدل با هدف کمینه کردن هزینه بهره برداری و زمان اتلاف وقت مسافر و بار به محاسبه پارامترهای مربوط به برنامه ریزی از جمله بسامد سرویس، برنامه توقف قطارها و حداقل تعداد قطارهای مورد نیاز پرداخته شده است. سپس کاربرد مدل در خط تهران- قم- اراک- دورود منجر به این نتیجه شده است که در سال 1400 حداقل به 9 زوج قطارهای مسافری و 18 زوج قطار باری برای سرویس دهی در این خط نیاز است تا سطح خدمات بهینه را از لحاظ هزینه و زمان در آن داشته باشیم.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 877

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 151 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

FAGHANI NOBARI H.

نشریه: 

AMIRKABIR

اطلاعات دوره: 
  • سال: 

    2004
  • دوره: 

    15
  • شماره: 

    59-C
  • صفحات: 

    115-124
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    272
  • دانلود: 

    0
چکیده: 

This paper presents the results of testing and analysis of reinforced concrete floor slab panels using Long form steel decking. The purpose of the study is to assess the contribution of steel decking to the stiffness of the slab system and its influence on the short-term and long-term deflections. The tests were carried out under sustained loads for a period of 260 days. The study indicated that the decking steel can be included in the geometric properties of the slab section for the purpose of satisfying SERVICEABILITY requirements on deflections. A set of conclusions and recommendations drawn from this investigation are presented.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 272

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1396
  • دوره: 

    8
  • شماره: 

    3
  • صفحات: 

    423-433
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1093
  • دانلود: 

    505
چکیده: 

حرکت گروهی افراد در پیاده رو ها به دلیل خصوصیات متفاوتی که با حرکت عابرین تنها دارد، می تواند تاثیر قابل ملاحظه ای در جریان حرکتی عابرین و درنتیجه سطح رضایتمندی آنها از پیاده رو داشته باشد. در این مقاله از یک روش جدید تحت عنوان میکرو شبیه سازی برای ارزیابی سطح سرویس پیاده روها در کشور استفاده شده است. برای این کار شش سناریوی مختلف شامل حضور 10، 20 و 30 درصدی گروه دو نفره، 10 و 20 درصدی گروه سه نفره و حضور ترکیبی 25 درصد گروه دو نفره و 15درصد گروه سه نفره یکبار برای پیاده رو با عرض 3 متر و یکبار برای پیاده رو با عرض 4.5 متر در نظر گرفته شد. علاوه بر این برای به دست آوردن پارامترهای ورودی نرم افزار، 8 پیاده رو در 4 منطقه از شهر تهران مورد مطالعه قرار گرفت. طبق نتایج تحقیق میانگین فضای حرکتی با افزایش ترافیک گروه های عابر پیاده کاهش می یابد. همچنین روند کاهش سطح سرویس در پیاده رو عریض تر با شیب ملایم تری نسبت به پیاده رو باریک تر اتفاق می افتد. نتایج این تحقیق، در کنار آیین نامه های موجود می تواند به عنوان راهنمایی مناسب برای مدیران و طراحان شهری برای بهبود روند طراحی های مسیرهای پیاده شهری، افزایش رضایتمندی شهروندان و صرفه جویی در هزینه انجام پروژه ها در کشور مورد استفاده قرار گیرد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1093

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 505 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

GHOLAMHOSEINI ALIREZA

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    8
  • شماره: 

    1
  • صفحات: 

    87-101
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    308
  • دانلود: 

    0
چکیده: 

Relatively little research has been reported on the time-dependent in-service behavior of composite concrete slabs with profiled steel decking as permanent formwork and little guidance is available for calculating long-term deflections. The drying shrinkage profile through the thickness of a composite slab is greatly affected by the impermeable steel deck at the slab soffit, and this has only recently been quantified. This paper presents the results of long-term laboratory tests on composite slabs subjected to both drying shrinkage and sustained loads. Based on laboratory measurements, a design model for the shrinkage strain profile through the thickness of a slab is proposed.The design model is based on some modifications to an existing creep and shrinkage prediction model B3. In addition, an analytical model is developed to calculate the time-dependent deflection of composite slabs taking into account the time-dependent effects of creep and shrinkage.The calculated deflections are shown to be in good agreement with the experimental measurements.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 308

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 1
نویسندگان: 

MAGHSOUDI A.A. | AKBARZADEH BENGAR H.

نشریه: 

Scientia Iranica

اطلاعات دوره: 
  • سال: 

    2011
  • دوره: 

    18
  • شماره: 

    1
  • صفحات: 

    36-44
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    173
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 173

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
نشریه: 

Scientia Iranica

اطلاعات دوره: 
  • سال: 

    2024
  • دوره: 

    31
  • شماره: 

    Transactions on Computer Science & Engineering and Electrical Engineering (D)21
  • صفحات: 

    1178-1196
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1
  • دانلود: 

    0
چکیده: 

Optimal planning and management of electric vehicle parking lots (EVPLs) can be an effective approach for improving the operation of both the distribution system and traffic networks. However, the limited land areas of cities can be an obstacle for constructing a large number of parking lots (PLs). This paper proposed a model for optimal siting and sizing of EVPLs as well as their charging schedule to maximize the total profit of their owners, while maximum parking demand of plug-in electric vehicles (PEVs) can be satisfied. In the proposed model, the purpose of trips, number of PEVs, plus their arrival and departure time in different urban areas are considered. Distribution network constraints are also taken into account using linearized load flow equations. The proposed model is implemented in a 37-bus distribution system coupled with a 25-node transportation network which includes four different areas in terms of PEV travel type. The simulation results show the effectiveness of the proposed model to cover the parking demand of PEVs with a limited number of PLs.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نشریه: 

Scientia Iranica

اطلاعات دوره: 
  • سال: 

    2024
  • دوره: 

    31
  • شماره: 

    Transactions on Computer Science & Engineering and Electrical Engineering (D)14
  • صفحات: 

    1178-1196
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1
  • دانلود: 

    0
چکیده: 

Optimal planning and management of electric vehicle parking lots (EVPLs) can be an effective approach for improving the operation of both the distribution system and traffic networks. However, the limited land areas of cities can be an obstacle for constructing a large number of parking lots (PLs). This paper proposed a model for optimal siting and sizing of EVPLs as well as their charging schedule to maximize the total profit of their owners, while maximum parking demand of plug-in electric vehicles (PEVs) can be satisfied. In the proposed model, the purpose of trips, number of PEVs, plus their arrival and departure time in different urban areas are considered. Distribution network constraints are also taken into account using linearized load flow equations. The proposed model is implemented in a 37-bus distribution system coupled with a 25-node transportation network which includes four different areas in terms of PEV travel type. The simulation results show the effectiveness of the proposed model to cover the parking demand of PEVs with a limited number of PLs.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1402
  • دوره: 

    13
  • شماره: 

    34
  • صفحات: 

    27-39
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    65
  • دانلود: 

    7
چکیده: 

فشار سینه کار به طورکلی به دو روش اصلی حالت حدی نهایی و حالت حدی سرویس محاسبه می شود. در این میان، حالت حدی نهایی، حالت بحرانی جابجایی زمین در موقعیت سینه کار است که منجر به ناپایداری سینه کار و ریزش آن می شود. در این روش، در محاسبات فشار نگهداری سینه کار تونل، تغییر شکل های زمین در نظر گرفته نمی شود. روش حالت حدی سرویس، بیشتر مرتبط با مقدار افت حجمی و نشست سطحی حداکثر زمین است. روش های موجود برای برآورد فشار سینه کار در حالت حدی سرویس عموماً بر اساس نتایج آزمایش های آزمایشگاهی (آزمایش گریز از مرکز تونل) یا داده های تجربی نسبتاً قدیمی توسعه یافته اند. در این مقاله برای برآورد فشار سینه کار در حالت حدی سرویس از مدل سازی عددی با نرم افزار V 20 PLAXIS 3D استفاده شده است. با توجه به گستردگی حالت های مدل سازی، شرایط هندسی (قطر حفاری 9 متر) و ژئوتکنیکی خطوط متروی تهران برای مدل سازی در نظر گرفته شد. برای صحت سنجی نتایج مدل سازی ها از نتایج نشست سنجی پروژه توسعه جنوبی خط 6 مترو تهران استفاده شده است. بر این اساس، مدل های مربوط به مقاطعی که مقادیر نشست آن ها بیشتر از 8 و کمتر از 8 میلی متر است به ترتیب در حالت زه کش شده و زه کش نشده تطبیق نتایج بهتری با نتایج واقعی نشست سطحی دارند. همچنین نتایج تحلیل حساسیت انجام شده بر روی پارامترهای مختلف ورودی مدل ها در هر دو حالت زه کش شده و زه کش نشده نشان می دهد که تغییر مقدار مدول الاستیسیته، بیشترین تأثیر را بر میزان تغییر نشست سطح زمین دارد. هدف اصلی در این مطالعه برآورد عدد پایداری و به دست آوردن روابطی تجربی بین عدد پایداری و سایر پارامترها است. بر این اساس با استفاده از نتایج مدل سازی های عددی و روش تحلیل رگرسیون ساده و چندگانه، سه رابطه جدید برای برآورد عدد پایداری در حالت زه کش نشده و یک رابطه تجربی جدید برای عدد پایداری متناظر در حالت زه کش شده ارائه شده است. در این روابط از پارامترهای مدول یانگ، ارتفاع سطح آب زیرزمینی و افت حجمی استفاده شده است. ضریب تعیین (R2) فرمول تجربی حالت زه کش شده برابر با 68 درصد و ضریب تعیین (R2) سه فرمول حالت زه کش نشده برابر با 66 درصد، 48 درصد و 66 درصد است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 65

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 7 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نشریه: 

استقلال

اطلاعات دوره: 
  • سال: 

    1386
  • دوره: 

    26
  • شماره: 

    1
  • صفحات: 

    79-91
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1229
  • دانلود: 

    206
چکیده: 

نشانه خدمت دهی راه (PSR) یکی از معیارهای مهم در تعیین زمان تعمیر و مرمت راه است. دراین مقاله مدلهایی برای تعیین رابطه PSR و سرعت آزاد عبور در تسهیلات تحت جریان ترافیکی پیوسته توسعه یافته است. سپس براساس روابط مختلف موجود بین سرعت و ظرفیت، تاثیر وضعیت روسازی برظرفیت ارایه شده است. دو وسیله نقلیه متداول به همراه ده نفر ارزیاب 23 مقطع از دو مسیر اصلی جدا شده و بزرگراه با شرایط هندسی مشابه و وضعیت متفاوت روسازی را مورد ارزیابی قرار داده اند. به منظور تعیین خدمت دهی راه مقاطع آزمون به گونه ای انتخاب شده اند که در طولی حداقل برابر 400 متر ناهمواریها یکنواخت باشد و نیز مقاطع به گونه ای انتخاب شده اند که طیف قابل قبولی از خدمت دهی را پوشش دهند. برای ساخت مدل 9 مقطع در مسیری جداشده شش خطه (هر طرف سه خط) با شیب کمتر از دودرصد و برای اعتبارسنجی از چهارده مقطع دیگر با شرایط هندسی مشابه استفاده شد. در تحلیل داده از نرم افزار SAS استفاده شده است. نتایج نشان دهنده وجود ارتباطی معنی دار بین پارامترهاست. در این تحقیق مدل سرعت- نشانه خدمت دهی راه و سپس مدل ظرفیت- نشانه خدمتی دهی راه ارایه شده و نهایتا ضریب کاهش ظرفیت در نتیجه تقلیل کیفیت روسازی برای تکمیل ضرایب HCM 2000 ارایه شده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1229

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 206 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button